GF Series
For flush-with-floor installation

| Model | Intermittent Flow GPM |
Tapped Inlet and Outlet (in.) |
Static Holding Capacity (gal.) |
Greasy Sludge Capacity (lb.) |
Top to Center of Outlet A (in.) |
Bottom to Center | Width D (in.) |
Length E (in.) |
Height F (in.) |
Overall Length G (in.) |
Tapped Internal Vent + (in.) |
Bottom to Rear Vent + (in.) |
Shipping Weight (lb.) |
|
| of Inlet B (in.) |
of Outlet C (in.) |
|||||||||||||
| GF-1412 | 12 | 2 | 5.3 | 18 | 2.25 | 8.38 | 10.75 | 13 | 15.5 | 13 | 19.25 | — | — | 77 |
| GF-1815 | 16 | 2 | 10 | 60 | 2.5 | 11 | 13.25 | 13 | 21.25 | 16.25 | 26 | — | — | 108 |
| GF-1820 | 20 | 2 | 17 | 70 | 2.5 | 12 | 15 | 17 | 23 | 17.5 | 28.75 | — | — | 132 |
| GF-2420 | 30 | 3 | 31 | 90 | 3.13 | 14.5 | 17.88 | 21 | 27.25 | 21 | 34 | — | — | 203 |
| GF-2635† | 35 | 3* | 40 | 120 | 6 | 16.5 | 21 | 21 | 27.25 | 27 | 34 | 2 | 23.75 | 252 |
| GF-2824† | 40 | 4 | 54 | 180 | 5.25 | 21.5 | 25.75 | 23 | 29 | 31 | 37.75 | 2 | 27 | 304 |
| GF-3050† | 50 | 4 | 60 | 220 | 5.25 | 21.5 | 25.75 | 23 | 32.25 | 31 | 41 | 2 | 27 | 330 |
| GF-3224† | 60 | 4 | 67 | 250 | 5.25 | 21.5 | 25.75 | 23 | 35.75 | 31 | 43 | 2 | 27 | 377 |
| GF-3475† | 75 | 4 | 80 | 300 | 4.75 | 22 | 26.25 | 25.5 | 35.75 | 31 | 44.38 | 2 | 27 | 398 |
| GF-3628† | 100 | 4 | 110 | 350 | 4.75 | 22 | 26.25 | 32.75 | 38.25 | 31 | 46.63 | 2 | 27 | 507 |
| GF-23-LO | 16 | 2 | 10 | 65 | 1.25 | 6 | 8.75 | 17 | 23 | 10.63 | 28.75 | — | — | 111 |
| GF-25-LO | 20 | 2 | 21 | 80 | 3 | 6.5 | 10.25 | 23 | 29 | 13.25 | 33.75 | — | — | 186 |
| GF-30-LO | 30 | 3* | 23 | 90 | 3 | 6.5 | 10.25 | 23 | 33 | 13.25 | 39.75 | — | — | 195 |
| GF-36-LO | 35 | 3* | 28 | 108 | 3 | 6.5 | 10.25 | 23 | 39 | 13.25 | 45.75 | — | — | 257 |
| GF-45-LO† | 40 | 3* | 37 | 200 | 5 | 6.75 | 11 | 23 | 47.25 | 16 | 54 | 2 | 12.5 | 325 |
| GF-50-LO† | 50 | 3* | 41 | 250 | 5 | 6.75 | 11 | 23 | 52.25 | 16 | 59 | 2 | 12.5 | 341 |
† Anchor flange requires 3" extension.
* Also available with 2" inlet and outlet.
+ Internal vent connection is locatedon outlet wall, right-hand sideof the outlet.
Job Specification: Grease separators shall be Rockford Separators as manufactured by Rockford Sanitary Systems, Inc., Rockford, Illinois, and as noted on plans.
Separator Specifications: Furnish ______ Rockford Model GF-______ all-welded steel separators with integral extension of ______ " to grade, ______ g.p.m. intermittent flow, ______" tapped inlet and outlet with outlet vent connection, 2" tapped internal rear vent connection, ______lb. greasy sludge capacity, visible double-wall outside trap seal, non-removable separator screen and easily removable filter screen, removable 3/8" nonskid diamond treadplate cover for flush-with-floor installation suitable for pedestrian traffic and secured with stainless steel flat head screws, OPEX® Shop Coat coating inside, bituminous coating outside. Specify R (right hand) or L (left hand).
Optional Features: Concrete anchor flange with or without clamping ring, hub inlet and outlet connections, acid-resistant coating inside and outside. Epoxy coated. Filter medium, sediment basket. All stainless steel.

CONSTRUCTION
A compact, one-piece separator with integral extension built to exact requirements. The built-in strength of solid walls eliminates leaks caused by vibration and traffic in bolted down extensions.
Constructed of all-welded heavy gauge steel with corrosion-resistant coating, the separator features a removable nonskid flush-with-floor cover of heavy steel plate with leakproof and airtight gaskets, secured to the body of the unit with recessed stainless steel bolts, a removable separator screen and flow-regulator filter screen, a standard tapped inlet and outlet, and protective seal outlet. Concrete reinforcing anchor rings are optional.
Choice of outlet location saves space, labor, pipe and fittings. Outlet tee can be turned up to 90 degrees in either direction. Depth of inlet and outlet varies.
HOW TO ORDER
When an extension is needed to meet roughing-in on a flush-with-floor installation, select the separator of the right size and capacity. Then determine the required dimension A from the center of the outlet to the top of cover, and order accordingly. Dimension A is variable and can be specified to a fraction of an inch. The inlet opening is lower than the outlet opening to assure a wet inlet at all times. All separators with extensions have flush-with-floor covers.
NOTE: If dimension of extension A is not correct at Point of Order, built-on extensions available, priced on application.
Screen Clearance
| Model | Clearance Needed to Remove Screens for Cleaning | Bottom of Unit to Center of Outlet (in.) |
||
| M (in.) | L (Left Hand) (in.) | R (Right Hand) (in.) | ||
| GF-1412 | 12 | 8.25 | 8.25 | 10.75 |
| GF-1815 | 7 | 8.25 | 8.25 | 13.75 |
| GF-1820 | 7 | 7 | 7 | 15 |
| GF-2420 | 8 | 11.5 | 11.5 | 17.88 |
| GF-2635 | 8 | 11.5 | 11.5 | 20.75 |
| GF-2824 | 9 | 14 | 14 | 25.75 |
| GF-3050 | 9 | 14 | 14 | 25.75 |
| GF-3224 | 9 | 14 | 14 | 25.75 |
| GF-3475 | 12 | 14 | 14 | 26.25 |
| GF-3628 | 12 | 14 | 14 | 26.25 |
| GF-23-LO | 7 | 7 | 7 | 8.75 |
| GF-25-LO | 9 | 9 | 9 | 10.25 |
| GF-30-LO | 9 | 9 | 9 | 10.25 |
| GF-36-LO | 9 | 9 | 9 | 10.25 |
| GF-45-LO | 9 | 9 | 9 | 11 |
| GF-50-LO | 9 | 9 | 9 | 11 |
Specify M (Outlet opposite Inlet), L (Left Hand Outlet), or R (Right Hand Outlet) on your order.
TYPICAL INSTALLATIONS OF SEPARATORS SET FLUSH-WITH-FLOOR
Right Hand Shown
![]() |
![]() |