Model Intermittent
Flow GPM
Inlet/Outlet
Size
(in.)
SHC
Gallons
Top to
Center of
Outlet*
A (in.)
Bottom to Center Width
D (in.)
Length
E (in.)
Height
F (in.)
Overall
Length
G (in.)
Bottom
to Vent
(in.)
Vent
Size
(in.)
Number
of Covers
of Inlet
B (in.)
of Outlet
C (in.)
RLS-1815 10 2 10 6.25 13.75 13.75 13 21.25 20 26.63 17 2 1
RLS-1820 20 2 20 6.5 17.5 17.5 17 23 24 28.63 18.5 2 1
RLS-2420 30 2 30 9.12 17.88 17.88 21 27.25 27 35.5 24 2 1
RLS-2635* 40 2 40 7 24 24 21 27.25 31 35.5 25.5 2 1
RLS-2824* 50 2 50 6.75 24.25 24.25 23 29 31 38.68 27 2 1
RLS-3050* 60 2 60 5.25 25.75 25.75 23 32.25 31 41.75 27 2 1
RLS-3224* 70 2 70 5.25 25.75 25.75 23 35.75 31 45.25 27 2 1
RLS-3475* 80 2 80 7 27 27 25.5 35.75 34 45.25 28 2 1
RLS-3628* 100 2 110 7.75 26.25 26.25 32.75 38.25 34 47.75 28 2 1

* Larger units available.
* Anchor flange requies 3" extension.
• Stainless steel units are available.
* Install per your local code.
Double-wall construction available.

RLS Series

Heavy Commercial Lint Separators


Model Intermittent
Flow GPM
Inlet/Outlet
Size
(in.)
SHC
Gallons
Top to
Center of
Outlet*
A (in.)
Bottom to Center Width
D (in.)
Length
E (in.)
Height
F (in.)
Overall
Length
G (in.)
Bottom
to Vent
(in.)
Vent
Size
(in.)
Number
of Covers
of Inlet
B (in.)
of Outlet
C (in.)
RLS-20 150 4 150 9.5 26.25 26.25 26.75 60 36 73.63 27 3 2
RLS-25 200 6 200 11 29 29 26.75 80.75 40 102.5 32 3 3
RLS-40 300 6 300 15 40 40 26.75 80.75 55 102.5 45 3 3
RLS-55 400 6 400 22 53 53 26.75 80.75 75 102.5 65 3 3
RLS-70 500 6 500 16 44 44 38.75 80.75 60 102.13 51 3 3
RLS-100 750 6 750 20 55 55 38.75 98.75 75 120.5 65 3 4
RLS-135 1000 6 1000 20.5 51.5 51.5 50.75 104.75 72 126.5 60 3 4
RLS-200 1500 6 1500 20.5 75.5 75.5 50.75 104.75 96 126.5 84 3 4

* Larger units available. Call for specifications.
* Anchor flange requies 3" extension.
• 6" & larger - companion flange connection.
Double-wall construction available.

Job Specification: Lint separators shall be Rockford Lint Separators as manufactured by Rockford Sanitary Systems, Inc., Rockford, Illinois, and as noted on plans.

Separator Specifications: Furnish ______Rockford Model RLS-______ all-welded 10 gauge steel separators ______" tapped inlet and outlet with tapped ______" internal vent connection, visible double-wall outside trap seal, easily removable stainless steel filter for cleaning, removable 3/8" nonskid diamond treadplate cover(s) for flush-with-floor installation suitable for pedestrian traffic, sealed with heavy-duty leakproof gasket, secured with stainless steel flat head screws, OPEX® Shop Coat coating inside and bituminous coating outside for flush-with-floor installation.

Optional Features: OPEX® Shop Coat coating outside for on-the-floor installation, aluminum cover, anchor flange with or without clamping ring, integral extension to grade, epoxy coating, all stainless steel construction, double-wall construction. Cover(s) fastened with stainless steel vandal-proof bolts. Contact our Engineering Department.

RLS Series

Heavy Commercial Lint Separators


Model Static Holding Capacity
(gal.)
Tapped
Vent (in.)
Bottom to Center
of Outlet
A (in.)
Bottom to Vent
B (in.)
Width
C (in.)
Length
D (in.)
Height
E (in.)
Tapped Inlet and Outlet
F (in.)
Bottom to Center of Outlet
G (in.)
Weight (lb.)
RLS-5* 40 2 21 23 21.25 27.5 27 4 21 389
RLS-10* 67 2 25.75 27 23.25 36 31 4 25.75 605
RLS-15* 110 2 26.25 27 32.88 38.38 31 4 26.25 705
RLS-20 150 3 26.25 27 26.75 60 36 4 26.25 967
RLS-25 200 3 29 32 26.75 80.75 40 • 6 29 1180
RLS-40 300 3 40 45 26.75 80.75 55 • 6 40 1468
RLS-55 400 3 53 65 26.75 80.75 75 • 6 53 2020
RLS-70 500 3 44 51 38.75 80.75 60 • 6 44 2525
RLS-100 750 3 55 65 38.75 98.75 75 • 6 55 2650
RLS-135 1000 3 51.5 62 50.75 104.75 72 • 6 51.50 3300
RLS-200 1500 3 75.5 84 50.75 104.75 96 • 6 75.50 4500

LARGER UNITS AVAILABLE
* Anchor flange requires 3" extension.
• 6" & larger – companion flange connection.
Double-wall construction available.

Job Specification:Lint separators shall be Rockford Lint Separators as manufactured by Rockford Sanitary Systems, Inc., Rockford, Illinois, and as noted on plans.

Separator Specifications: Furnish ______Rockford Model RLS-______ all-welded 1/4" steel separators ______" tapped inlet and outlet with tapped ______" internal vent connection, visible double-wall outside trap seal, easily removable stainless steel filters for cleaning, removable 3/8" nonskid diamond treadplate cover(s) for flush-with-floor installation suitable for pedestrian traffic, sealed with heavy-duty leakproof gasket, secured with stainless steel flat head screws, OPEX® Shop Coat coating inside and bituminous coating outside for flush-with-floor installation.

Optional Features: OPEX® Shop Coat coating outside for on-the-floor installation, aluminum cover(s), anchor flange with or without clamping ring, integral extension to grade, epoxy coating, all stainless steel construction, double-wall construction. Cover(s) fastened with stainless steel vandal-proof bolts. Contact our Engineering Department.