• Specification Drawings

Choose from the options below to download specification drawings.









FORMAT:       

RP Series

Tested and certified to PDI-G101

RP-Series
Model Intermittent
Flow GPM
Static
Holding
Capacity
(gal.)
Greasy
Sludge
Capacity
(lb.)
Pipe Size
(in.)
Top to
Center of
Inlet and
Outlet A
(in.)
Side to
Center of
Inlet and
Outlet B
(in.)
Bottom to
Center of
Inlet and
Outlet C
(in.)
Width
D(in.)
Length
E(in.)
Height
F(in.)
Shipping
Weight
(lb.)
RP-4 4 3.75 18 2 3.5 5.125 7 13 18 10.5 40
RP-7 7 5.50 27 2 3.5 5.125 9.5 13 18 13 52
RP-10 10 7.50 42 2 3.5 6.125 9.5 15 20 13 55
RP-15 15 11.25 68 2 3.5 7.125 9.5 17 25 13 71
RP-20 20 13.00 77 3 3.5 8 9.5 18.75 27 13 80
RP-25 25 20.25 103 3 4.5 8.625 13.5 20 26 18 125
RP-35 35 30.00 153 4 4.5 8.625 17.5 20 28.5 22 130
RP-50 50 35.50 201 4 4.5 10.625 17.5 24 30 22 154
RP-20-LO* 20 11.25 68 3 3.5 10.125 6.5 23 32 10 130
RP-35-LO* 35 20.25 101 4 4.75 10.125 8.5 23 39 13.25 165
RP-50-LO* 50 38.25 219 4 5 10.125 11 23 52.25 16 210

Large Capacity Interceptors

Model Intermittent
Flow GPM
Static
Holding
Capacity
(gal.)
Greasy
Sludge
Capacity
(lb.)
Pipe Size
(in.)
Top to
Center of
Inlet and
Outlet A
(in.)
Side to
Center of
Inlet and
Outlet B
(in.)
Bottom to
Center of
Inlet and
Outlet C
(in.)
Width
D(in.)
Length
E(in.)
Height
F(in.)
Shipping
Weight
(lb.)
RP-75* 75 90.75 451 4 6 12.625 26 28 38 32 265
RP-100* 100 125 621 4 6 15.625 26 34 42 32 320
RP-125* 125 156 775 4 8 18 28 36 45 36 481
RP-150* 150 196 1021 4 10 18 30 36 52 40 518
RP-200* 200 293 1456 4 8 21 32 42 61 40 643
RP-250* 250 509 2529 4 9 21 54 42 61 63 969
RP-300* 300 630 3131 4 9 27 44 54 71 53 1124
RP-350* 350 780 3876 6 9 27 54 54 71 63 1265
RP-400* 400 970 4820 6 8 28.5 53 57 86 61 1400
RP-450* 450 990 4920 6 8 28.5 54 57 86 62 1475
RP-500* 500 1008 5009 6 8 28.5 55 57 86 63 1500

* Non-listed unit built in accordance with PDI G-101.
All units standard with no hub connections.
• Single bolt cover securement available.

Job Specification: Grease interceptors shall be Rockford Interceptors as manufactured by Rockford Sanitary Systems, Inc., Rockford, Illinois, and as noted on plans.

Interceptor Specifications: Furnish ______Rockford Model RP-______ PDI listed (thru 50 GPM only) all-welded steel interceptors for on-the-floor, partially recessed, or flush-with-floor installation, ______ g.p.m. intermittent flow, ______ lb. grease capacity, ______" no-hub inlet and outlet connections, flow control device, removable nonskid diamond treadplate cover for flush-with-floor installation suitable for pedestrian traffic or reinforced for light traffic, secured with stainless steel flat head screws, heavy-duty leakproof gasket. Units are furnished standard with enamel coating inside and outside. Supplied standard with air relief bypass. Bituminous coating outside for recessed installation optional at no extra charge.

Optional Features: Tapped inlet/outlet connections, epoxy coating, integral extensions, and stainless steel construction.